We are happy to help you with making a calculation
Get in contact with usSide wall ventilation is a natural form of ventilation. In this case, the film is mounted on the side wall of the greenhouse on a winding tube. Powered by a fixed motor gearbox with one or two telescopic arms attached, almost the entire side wall can be opened. In this way, ventilation can be further optimised.
Article | Description | T (50/60Hz) [Nm] | n (50/60Hz) [rpm] | L [mm] | D [mm] | P (50/60Hz) [kW] | I (@ Y) (50/60Hz) [A] | I (@ Δ) (50/60Hz) [A] | m [kg] |
P.GW10.3.400.52.K | GW10 5.2 3ph 400V | 100 / 80 | 5,2 / 6,2 | 191 | 124 | 0,18 / 0,22 | 0,7 / 0,7 | 1,2 / 1,2 | 24 |
2 P.GW10.3.400.52.K 11 GW10 5.2 3ph 400V 12 13 P.GW10.400.26.K.jpg 14 15 CAT_P.GW10.400.26.K_2D.gif 17 16 10 | |||||||||
P.GW30.400.52.K | GW30 5.2 3ph 400V | 300 / 240 | 5,2 / 6,2 | 220 | 145 | 0,37 / 0,44 | 1,2 / 1,2 | 2,1 / 2,1 | 27 |
2 P.GW30.400.52.K 11 GW30 5.2 3ph 400V 12 13 P.GW30.400.26.K.jpg 14 15 CAT_P.GW30.400.26.K_2D.gif 17 16 10 |
Article | Description | T (50/60Hz) Nm | n (50/60Hz) [rpm] | i [-] | s [-] | P (50/60Hz) [kW] | I (@ Y) (50/60Hz) [A] | I (@ Δ) (50/60Hz) [A] | m [kg] |
P.GWM15.1.400.52.K | GWM15 5.2 3ph 400V for CC-set | 150 / 120 | 5,2 / 6,2 | 264 | 1,50-84 | 0,25 / 0,30 | 0,8 / 1,0 | 1,4 / 1,7 | 17 |
2 P.GWM15.1.400.52.K 11 GWM15 5.2 3ph 400V for CC-set 12 13 P.GWM30.1.400.26.K.jpg 14 15 CAT_P.GWM30.400.26.K_2D.gif 17 16 10 | |||||||||
P.GWM30.1.400.26.K | GWM30 2.6 3ph 400V for CC-set | 300 / 240 | 2,6 / 3,1 | 505 | 0,75-42 | 0,25 / 0,30 | 0,8 / 1,0 | 1,4 / 1,7 | 17 |
2 P.GWM30.1.400.26.K 11 GWM30 2.6 3ph 400V for CC-set 12 13 P.GWM30.1.400.26.K.jpg 14 15 CAT_P.GWM30.400.26.K_2D.gif 17 16 10 |
Article | Article name | A [mm] | L [mm] | m [kg] |
P.MP.GW.R.A163 | Mounting plate GW straight A163 L174 | 163 | 174 | 1,2 |
Article | Article name | A [mm] | L [mm] | m [kg] |
P.MP.GWM.R.A163 | Mounting plate GWM straight A163 L204 | 163 | 204 | 0,9 |
Article | Description | D1 [mm] | D2 [mm] | L1 [mm] | L2 [mm] | L3 [mm] | L4 [mm] | m [kg] |
P.KS.TSP.D20.D18 | Coupling piece telescopic arm GW10 | 18 | 32 | 26 | 52 | 7 | 10 | 0,3 |
2 P.KS.TSP.D20.D18 11 Coupling piece telescopic arm GW10 12 13 P.KS.TSP.D20.D00.jpg 14 15 CAT_P.KS.TSP.D20.D00_2D.gif 16 10 | ||||||||
P.KS.TSP.D20.D25 | Coupling piece telescopic arm GW30 | 25 | 42 | 41 | 55 | 7,5 | 20 | 0,5 |
2 P.KS.TSP.D20.D25 11 Coupling piece telescopic arm GW30 12 13 P.KS.TSP.D20.D00.jpg 14 15 CAT_P.KS.TSP.D20.D00_2D.gif 16 10 |
Article | Description | L [mm] | H [mm] | T [Nm] | m [kg] |
P.TSP40.H1400 | TSP40 telescopic arm for height 1.4m | 1400 | 1408 | 40 | 5 |
P.TSP40.H1800 | TSP40 telescopic arm for height 1.8m | 1800 | 1808 | 40 | 6 |
P.TSP40.H2000 | TSP40 telescopic arm for height 2.0m | 2000 | 2008 | 40 | 6 |
P.TSP40.H2500 | TSP40 telescopic arm for height 2.5m | 2500 | 2508 | 40 | 7 |
P.TSP40.H3300 | TSP40 telescopic arm for height 3.3m | 3300 | 3308 | 40 | 9 |
P.TSP40.H4000 | TSP40 telescopic arm for height 4.0m | 4000 | 4008 | 40 | 11 |
Article | Description | D1 [mm] | D2 [mm] | L1 [mm] | L2 [mm] | m [kg] |
P.LT100.02 | 1" Weld joint for univ.joint with hole Ø9 | 27 | 20 | 72 | 52 | 0,3 |
2 P.LT100.02 14 1" Weld joint for univ.joint with hole Ø9 15 16 P.LT100.02.SL04EZ.jpg 17 10 CAT_P.LT100.02.SL04EZ_2D.gif |
Article | Description | D1 [mm] | D2 [mm] | L1 [mm] | L2 [mm] | L3 [mm] | m [kg] |
P.KBS50.02.TSP | Coupling piece telescopic arm Tube Ø50 mm | 20 | 50 | 151 | 20 | 61 | 0,7 |
2 P.KBS50.02.TSP 11 Coupling piece telescopic arm Tube Ø50 mm 12 13 P.KBS50.02.TSP.jpg 14 15 CAT_P.KBS50.02.TSP_2D.gif 10 |
Article | Description | m [kg] |
P.BHZ.01.GW10 | GW10 enclosure grey with bolts | 1,4 |
Controlled ventilation is a must for an optimal climate in poly greenhouses. Ventilation is realised by means of continuous windows in the ridge of the greenhouse or by roll-up walls. We have the knowledge, expertise and extensive product range to contribute to an optimal climate for the best results.
We are happy to help you with making a calculation
Get in contact with usSide wall ventilation is a natural form of ventilation in which the film is mounted on the side wall of the greenhouse on a winding tube. Opening of the entire wall is possible via a GXP10 motor gearbox mounted on a guide tube. The plastic band that is wrapped and not stretchable bears the weight of the motor gearbox. In this way, ventilation is optimised.
Article | Description | T (50/60Hz) [Nm] | n (50/60Hz) [rpm] | P (50/60Hz) [kW] | I (@ Δ) (50/60Hz) [A] | I (@ Y) (50/60Hz) [A] | m [kg] |
P.GXP10.400.40.KBS.T | GXP10-4.0 400V 3~ 50Hz for KBS Trop.iso | 100 / 80 | 4,0 / 4,8 | 0,18 / 0,22 | 1,2 / 1,2 | 0,7 / 0,7 | 11 |
2 P.GXP10.400.40.KBS.T 11 GXP10-4.0 400V 3~ 50Hz for KBS Trop.iso 12 13 P.GXP10.400.40.KBS.T.jpg 14 15 CAT_P.GXP10.400.40.KBS.T_2D.gif 10 |
Article | Description | L [mm] | D [mm] | m [kg] |
P.BHZ.01.GXP10 | GXP10 enclosure aluminium | 550 | 55 | 1,0 |
Article | Description | D1 [mm] | D2 [mm] | L1 [mm] | L2 [mm] | m [kg] |
P.KBS32.01.D19 | Coupling bush GXP tube Ø32x1.5; 25x25x1.5 | 40 | 19 | 118 | 80 | 0,6 |
2 P.KBS32.01.D19 11 Coupling bush GXP tube Ø32x1.5; 25x25x1.5 12 13 P.KBS32.01.D19.jpg 14 10 CAT_P.KBS32.01.D19_2D.gif | ||||||
P.KBS50.01.D19 | Coupling to Tube Ø50mm GXP10 | 50 | 19 | 105 | 70 | 0,4 |
2 P.KBS50.01.D19 11 Coupling to Tube Ø50mm GXP10 12 13 P.KBS50.08.D00.jpg 14 10 CAT_P.KBS50.08.D00_2D.gif |
Article | Description | m [kg] |
P.BL.02.GXP10 | GXP lower guide mounting bracket | 0,4 |
P.BL.04.GXP10 | GXP10 upper guide mounting bracket | 0,4 |
Article | Description | P max [W] |
P.KAB.4.075 | Cable 4x0,75mm² GXP per meter (Power) | 1380 |
P.KAB.7.05 | Cable (steering control) 7x0,5mm² 1m | - |
Article | Description | L [m] | m [kg] |
P.KRP.15.16.30 | Cable chain GXP 15x16mm 3.0 m + mounting set | 3,0 | 0,8 |
Controlled ventilation is a must for an optimal climate in poly greenhouses. Ventilation is realised by means of continuous windows in the ridge of the greenhouse or by roll-up walls. We have the knowledge, expertise and extensive product range to contribute to an optimal climate for the best results.
We are happy to help you with making a calculation
Get in contact with usSide wall ventilation is a natural form of ventilation. In this case, the film is mounted on the side wall of the greenhouse on a winding tube. Powered by a guide tube mounted GXP10 motor gearbox, almost the entire side wall can be opened. A counterweight compensates for the weight of the motor gearbox. In this way, ventilation can be further optimised.
Article | Description | T (50/60Hz) [Nm] | n (50/60Hz) [rpm] | P (50/60Hz) [kW] | I (@ Δ) (50/60Hz) [A] | I (@ Y) (50/60Hz) [A] | m [kg] |
P.GXP10.400.40.KBS.T | GXP10-4.0 400V 3~ 50Hz for KBS Trop.iso | 100 / 80 | 4,0 / 4,8 | 0,18 / 0,22 | 1,2 / 1,2 | 0,7 / 0,7 | 11 |
2 P.GXP10.400.40.KBS.T 11 GXP10-4.0 400V 3~ 50Hz for KBS Trop.iso 12 13 P.GXP10.400.40.KBS.T.jpg 14 15 CAT_P.GXP10.400.40.KBS.T_2D.gif 10 |
Article | Description | L [mm] | D [mm] | m [kg] |
P.BHZ.01.GXP10 | GXP10 enclosure aluminium | 550 | 55 | 1,0 |
Article | Description | D1 [mm] | D2 [mm] | L1 [mm] | L2 [mm] | m [kg] |
P.KBS32.01.D19 | Coupling bush GXP tube Ø32x1.5; 25x25x1.5 | 40 | 19 | 118 | 80 | 0,6 |
2 P.KBS32.01.D19 11 Coupling bush GXP tube Ø32x1.5; 25x25x1.5 12 13 P.KBS32.01.D19.jpg 14 10 CAT_P.KBS32.01.D19_2D.gif | ||||||
P.KBS50.01.D19 | Coupling to Tube Ø50mm GXP10 | 50 | 19 | 105 | 70 | 0,4 |
2 P.KBS50.01.D19 11 Coupling to Tube Ø50mm GXP10 12 13 P.KBS50.08.D00.jpg 14 10 CAT_P.KBS50.08.D00_2D.gif | ||||||
P.KBS50.02.D19 | Coupling to Tube Ø50 Twinrol GXP10 | 50 | 19 | 100 | 70 | 0,3 |
2 P.KBS50.02.D19 11 Coupling to Tube Ø50 Twinrol GXP10 12 13 P.KBS50.08.D00.jpg 14 10 CAT_P.KBS50.08.D00_2D.gif |
Article | Description | m [kg] |
P.BL.02.GXP10 | GXP lower guide mounting bracket | 0,4 |
P.BL.04.GXP10 | GXP10 upper guide mounting bracket | 0,4 |
Article | Description | P max [W] |
P.KAB.4.075 | Cable 4x0,75mm² GXP per meter (Power) | 1380 |
P.KAB.7.05 | Cable (steering control) 7x0,5mm² 1m | - |
Article | Description | L [m] | m [kg] |
P.KRP.15.16.30 | Cable chain GXP 15x16mm 3.0 m + mounting set | 3,0 | 0,8 |
Article | Description | L [mm] | D [mm] | m [kg] |
P.CONTRA.GXP10.01 | Contra gewicht GXP10 Ø55mm 10kg | 550 | 55 | 10 |
Controlled ventilation is a must for an optimal climate in poly greenhouses. Ventilation is realised by means of continuous windows in the ridge of the greenhouse or by roll-up walls. We have the knowledge, expertise and extensive product range to contribute to an optimal climate for the best results.
We are happy to help you with making a calculation
Get in contact with usSide wall ventilation is a natural form of ventilation. In this case, the film is mounted on the side wall of the greenhouse on a winding tube. Driven by a guide tube mounted motor gearbox, almost the entire side wall can be opened. A counterweight compensates for the weight of the motor gearbox. In this way, ventilation can be further optimised.
Article | Description | T (50/60Hz) Nm | n (50/60Hz) [rpm] | i [-] | s [-] | P (50/60Hz) [kW] | I (@ Y) (50/60Hz) [A] | I (@ Δ) (50/60Hz) [A] | m [kg] |
P.GWM30.1.400.26.K | GWM30 2.6 3ph 400V for CC-set | 300 / 240 | 2,6 / 3,1 | 505 | 0,75-42 | 0,25 / 0,30 | 0,8 / 1,0 | 1,4 / 1,7 | 17 |
2 P.GWM30.1.400.26.K 11 GWM30 2.6 3ph 400V for CC-set 12 13 P.GWM30.1.400.26.K.jpg 14 15 CAT_P.GWM30.400.26.K_2D.gif 17 16 10 | |||||||||
P.GWM45.1.400.26.K | GWM45 2.6 3ph 400V for CC-set | 450 / 360 | 2,6 / 3,1 | 505 | 0,75-42 | 0,37 / 0,44 | 1,0 / 1,2 | 1,7 / 2,1 | 17 |
2 P.GWM45.1.400.26.K 11 GWM45 2.6 3ph 400V for CC-set 12 13 P.GWM30.1.400.26.K.jpg 14 15 CAT_P.GWM30.400.26.K_2D.gif 17 16 10 |
Article | Description | D1 [mm] | D2 [mm] | L1 [mm] | L2 [mm] | m [kg] |
P.KBS32.01.D25 | Coupling to tube Ø32x1.5, D25 | 28 | 25 | 128 | 80 | 0,6 |
2 P.KBS32.01.D25 11 Coupling to tube Ø32x1.5, D25 12 13 P.KBS32.01.D25.jpg 14 10 CAT_P.KBS32.01.D25_2D.gif | ||||||
P.KBS50.02.D25 | Coupling to tube Ø50 Twin GW30/GW80 | 50 | 25 | 120 | 70 | 0,5 |
2 P.KBS50.02.D25 11 Coupling to tube Ø50 Twin GW30/GW80 12 13 P.KBS50.08.D00.jpg 14 10 CAT_P.KBS50.08.D00_2D.gif |
Article | Description | L [mm] | B [mm] | H [mm] | D [mm] | m [kg] |
P.BL.R.GWM.01 | GWM Roller bracket for tube Ø32/1" | 300 | 135 | 70 | 32/33.7 | 1,4 |
2 P.BL.R.GWM.01 11 GWM Roller bracket for tube Ø32/1" 12 13 P.BL.R.GWM.01.jpg 14 10 CAT_P.BL.R.GWM.01_2D.gif |
Article | Description | m [kg] |
P.BL.02.GXP10 | GXP lower guide mounting bracket | 0,4 |
P.BL.04.GXP10 | GXP10 upper guide mounting bracket | 0,4 |
Article | Description | P max [W] |
P.KAB.4.075 | Cable 4x0,75mm² GXP per meter (Power) | 1380 |
P.KAB.7.05 | Cable (steering control) 7x0,5mm² 1m | - |
Article | Description | L [m] | m [kg] |
P.KRP.15.16.30 | Cable chain GXP 15x16mm 3.0 m + mounting set | 3,0 | 0,8 |
Article | Description | L [mm] | D [mm] | m [kg] |
P.CONTRA.GWM.01 | Contra gewicht Ø70mm GWM - 14 kg | 460 | 55 | 14 |
Controlled ventilation is a must for an optimal climate in poly greenhouses. Ventilation is realised by means of continuous windows in the ridge of the greenhouse or by roll-up walls. We have the knowledge, expertise and extensive product range to contribute to an optimal climate for the best results.
De Gier Drive Systems
+ 31 174 29 20 89
Westlandseweg 9
2291 PG Wateringen
Netherlands
+31 174 29 20 89
sales@degierdrivesystems.com
We would like to get in touch with you. After filling in this form you can download all documents on our website. The download will start immediately after you have completed the form.
We would like to get in touch with you. After filling in this form you can download all documents on our website. The download will start immediately after you have completed the form.
We would like to get in touch with you. After filling in this form you can download all documents on our website. The download will start immediately after you have completed the form.
We would like to get in touch with you. After filling in this form you can download all documents on our website. The download will start immediately after you have completed the form.